Skip to main content

Table 3 3D model parameters, obtained from the 1D model with zero protected length

From: Are standing osmotic gradients the main driver of cerebrospinal fluid production? A computational analysis

Parameters

Symbol

Value

Mean − SD

Mean

Mean + SD

Microvillus length (µm)

\({l}_{\text{mv}}\)

2.329

1.875

1.959

Microvillus radius (µm)

\({r}_{\text{mv}}\)

0.087

0.104

0.098

Microvilli surface density (1/µm2)

\(\sigma\)

10.0

15.3

12.6

ChP apparent area (cm2)

\({A}_{\text{app}}\)

3.54

3.85

3.87

Protected length (µm)

\({l}_{\text{prot}}\)

0

0

0

Diffusion coefficient (cm2/s)

\(D\)

1.12 · 10–5

1.06 · 10–5

1.08 · 10–6

Bulk solute concentration (Osm)

\({C}_{0}\)

0.2967

0.3129

0.3041

Luminal membrane permeability (cm/s · Osm)

\({L}_{\text{p}}\)

5.03 ·  10–6

9.82 · 10–6

2.17 · 10–5

CSF density (g/mL)

\(\rho\)

1.0002

1.0001

1.0002

Measured CSF production rate (µL/min)

\({Q}_{\text{meas}}\)

7.071

7.346

7.072

CSF viscosity (Pa · s)

\(\mu\)

8.9 · 10–4

8.9 · 10–4

8.9 · 10–4

  1. The three columns (mean − SD, mean, and mean + SD) represent the set of parameter values that yield the mean CSF production rate (center column) or its mean plus or minus standard deviation value (right and left columns, respectively). Note that CSF viscosity is not considered in the 1D model